If you’ve ever stood beside a commercial chiller unit as our service technicians do every day, watching a unit struggle to cool a warehouse on a 95-degree afternoon, you know how quickly small, unaddressed issues can derail operations. Over the 12 years I’ve worked as a chiller supplier, one of the most common problems I see (and one that’s far easier to prevent than most building managers realize) is incorrect refrigerant charge. I’ve lost count of how many customers call us in a panic because their chiller’s performance dropped 20% or more, and when we test the refrigerant charge, it’s either 15% too low or 10% too high. It’s not a tricky, hidden flaw—it’s a simple mistake that snowballs because no one checks the charge regularly the way they check air filters or coolant levels. Chiller

Let’s break this down, because I want you to understand why refrigerant charge matters more than you might think, especially when it comes to the chillers we design and supply for retail spaces, hospitals, and manufacturing plants. At its core, a chiller works by moving refrigerant through a closed loop of four main components: the compressor, condenser, expansion valve, and evaporator. The refrigerant’s job is to absorb heat from the indoor water stream (that’s how you get cold air for your building) and release that heat outside to the atmosphere. The exact amount of refrigerant needed to do this perfectly is tailored to each chiller model, based on its size, the type of refrigerant it uses, and its intended application. Deviate even a little from that specific charge, and the entire cycle falls out of balance.
First, let’s talk about undercharged chillers—this is the more common issue, in my experience. Undercharging happens when refrigerant leaks out slowly over time, often from small pinholes in lines that are hard to spot until performance drops. Here’s how that hits performance. When there’s less refrigerant than the system was designed for, the evaporator (the part that cools the water) doesn’t get enough refrigerant to fill its heat-exchanging surface completely. That means the water passing through the evaporator doesn’t cool as much as it should, because only a fraction of the coils are actually doing the heat-absorbing work. I saw a great example of this last month with a grocery store in Denver. Their 100-ton centrifugal chiller was supposed to keep their freezer cases and produce coolers running at set temperatures, but managers noticed the freezers were 10 degrees warmer than normal. When our technician tested the charge, it was 18% low. The evaporator only had 70% of its coils covered in active refrigerant, so the cooling capacity plummeted. The fix was a simple top-up, but if they’d waited much longer, the compressor would have started working overtime to make up for the missing refrigerant—and we’d have been looking at a $5,000 compressor repair instead of a $200 charge adjustment.
Undercharging doesn’t just lower cooling capacity, though. It also raises the discharge pressure on the compressor. Because there’s not enough refrigerant to carry all the heat from the evaporator, the compressor has to work harder to compress the remaining refrigerant to the pressure needed to release heat in the condenser. That higher discharge pressure means higher energy use—we’re talking 10-20% higher on average, based on our internal service data. For a 100-ton chiller running 24/7, that’s an extra $5,000 to $8,000 a year in electricity costs. And overtime work puts extra wear on the compressor, the most expensive part of your chiller. We’ve had customers skip annual charge checks and end up replacing a compressor 3 years early, just because a small leak turned into a big problem.
Now, overcharging is less common, but it’s just as damaging, and it’s usually the result of a bad service call or an incorrect top-up after maintenance. Overcharging happens when more refrigerant is added to the system than the design specifies. Here, the problem is the condenser, not the evaporator. Too much refrigerant fills the condenser’s heat-exchanging coils, so there’s not enough empty space for the refrigerant to turn back into a liquid after releasing heat. Liquid refrigerant can’t release heat as efficiently as vapor, so the condenser’s overall heat transfer drops. That leads to higher condenser pressure, which again makes the compressor work harder—raising energy use, just like undercharging. Worse, overcharging can cause liquid refrigerant to get pushed back into the compressor, a problem called liquid slugging. Liquid doesn’t compress the way vapor does, so it can bend compressor valves or damage the piston or turbine. We saw this two years ago with a manufacturing plant in Cleveland. Their chiller was serviced by a company that overcharged it by 12 pounds of R-134a (it was a 500-ton unit, so that’s a significant overcharge). The compressor ran for three weeks, but the liquid slugging caused a valve failure, and the entire compressor had to be replaced—costing them over $15,000 in parts and downtime. That’s a perfect example of how even a small mistake in charging can spiral into a major headache.
It’s not just performance and cost that are at stake, either. Refrigerant type matters here, too. Modern chillers are increasingly using low-GWP (global warming potential) refrigerants like R-32 or R-454B, which are designed to be more environmentally friendly, but they require even more precise charge levels than older refrigerants like R-22. I worked with a university in Boston last year that switched out their old R-22 chillers for new ones with R-454B. They skipped the initial charge verification after installation, because they thought “charge is charge.” Within two months, their chiller was 15% less efficient, and energy bills had jumped by $1,200 a month. When our team checked, the charge was off by 8%—the new refrigerant’s density is different, so the required charge amount is calibrated specifically for that gas, not an older one. That’s a key point I want everyone to remember: if you change refrigerant types, you can’t just top up the system with the new gas and hope for the best. You have to recalculate and verify the exact charge for that specific refrigerant in that specific chiller.
So, what can building managers and facility teams do to avoid these problems? First, don’t wait for performance to drop to check refrigerant charge. We recommend a full charge test every 6 months for chillers that run 24/7 (like hospitals, data centers, or manufacturing) and annually for chillers that run only during business hours. The test isn’t complicated—our technicians use pressure-temperature gauges and superheat/subcooling calculations to verify the charge is exactly where the manufacturer’s specs say it should be. Superheat is the term for how much the refrigerant vapor is heated above its boiling point in the evaporator; too low and you’re at risk of liquid slugging, too high and you’re undercharged. Subcooling is how much liquid refrigerant is cooled below its boiling point in the condenser; that’s where you can spot overcharging. A quick check of these two values takes less than 15 minutes, and it can catch a leak or incorrect charge before it causes damage.
Another tip: if your chiller is old and you’re thinking of replacing it, don’t forget that new models have different charge requirements. A lot of customers ask us, “Can I just use the same amount of old refrigerant in this new chiller?” and the answer is almost always no. Newer chillers are more efficient, so their charge volumes are calibrated to optimize that efficiency, usually with lower-GWP refrigerants that have different properties. When we install a new chiller for a customer, we do a full evacuation of the line set, pull a deep vacuum to remove moisture and air, and then charge it precisely to the model’s exact specifications—we never guess. That’s why we stand behind our chillers’ performance for 10 years, but only if the charge is maintained correctly.
I know facility managers are busy, and adding another task to their to-do list can feel overwhelming. That’s why we offer annual maintenance plans for all the chillers we supply, which include refrigerant charge testing, leak checks, and basic tune-ups. It’s a small investment—usually a few hundred dollars a month for a mid-sized chiller—but it saves thousands in energy costs and emergency repairs. I’ll be honest: I’d rather come out and spend 15 minutes verifying a charge than show up to replace a compressor that could have been avoided. That’s not just good for our business—it’s good for our customers, who rely on their chillers to keep their operations running smoothly.
Let me circle back to that Denver grocery store I mentioned earlier. After we charged their chiller correctly, their cooling capacity went up 19%—exactly what our calculations predicted. Their energy use dropped by 12%, and their freezers stayed at the correct temperature, so they didn’t lose any produce to spoilage. That’s the kind of win we see every time we address a charge issue. It’s a simple fix, but it makes a huge difference.
If you’re reading this and thinking, “I haven’t checked my chiller’s charge in a year,” don’t wait. A small leak can turn into a major problem faster than you think. Whether you have an existing chiller that’s underperforming or you’re in the market for a new one, we’re here to help. We don’t believe in one-size-fits-all solutions—we work with your specific building’s needs to make sure your chiller runs at peak efficiency, with the correct charge every time.

For anyone who’s tired of unexpected chiller downtime or rising energy bills from inefficient performance, reach out to our team to discuss your needs. We’ll come assess your current system, test your refrigerant charge, and give you recommendations that fit your budget. You don’t have to manage your chiller alone, and you don’t have to deal with avoidable issues because of a small charge mistake.
Specialty Dehumidifier References
ASHRAE Handbook: HVAC Systems and Equipment, American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2020.
Refrigeration and Air Conditioning Technology, 8th ed., Cengage Learning, 2017.
Air-Conditioning and Refrigeration Institute (ARI) Standard 550/590, 2019.
Hangzhou Dayu HVAC Engineering Co., Ltd.
As one of the most professional chiller manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. If you’re going to buy customized chiller made in China, welcome to get quotation from our factory. For price consultation, contact us.
Address: Room 1004, Building 1, Xicheng Business Tower, Xihu District, Hangzhou City, Zhejiang Province, China
E-mail: info@hi-hvac.com
WebSite: https://www.hi-hvac.com/